🧵 No jacket removal
Lay length is measured on the jacketed cable – the sample is not untwisted or stripped, so the result is accurate.
VisioCablePro® TLD measures the lay length of conductors in jacketed cables without removing the jacket. Traditional methods require stripping the jacket and untwisting the conductors, which alters the sample and prevents accurate measurement. Measurement is fully automatic: after a single click, the sensor travels along the sample by itself, and the results can be exported to a PC. The device measures in accordance with LV212 and LV122.
Sensor travelling along the cable sample
Lay length is measured on the jacketed cable – the sample is not untwisted or stripped, so the result is accurate.
One click starts the measurement – the sensor travels along the sample by itself. A slower pass gives a more accurate result.
Measurement compliant with LV212 and LV122, 1 mm accuracy, lay length from 10 to 800 mm.
Number of twists, measured length, sensor travel, minimum, maximum and average lay – saved to a text file via a PC.
| Product number | 402.0013.01 |
|---|---|
| Dimensions (W × L × H) | 1320 × 420 × 480 mm |
| Weight | 43 kg |
| Power supply | 100–240 V, 50–60 Hz |
| Power | max. 100 W |
| Material | Aluminium, stainless steel, PVC |
| Measuring accuracy | 1 mm |
| Standards | LV212, LV122 |
| Measurable lay length | min. 10 – max. 800 mm (at the standard measuring length; others on request after sending samples) |
| Measuring length | 800 mm (other on request) |
| Sample outer diameter | min. 2 mm (thin cables require an adapter; others on request after sending samples) |
| Sensor speed | Set in the configuration file – the slower, the more accurate |
| Results | Number of twists, measured section, sensor travel, minimum and maximum lay, average lay |
| Calibration | With a master sample |
When your customer requires conductor lay length measurement per LV212 or LV122 and you want to measure on the finished jacketed cable without untwisting the sample by hand. Insulation and jacket geometry on the cross-section of the same cable can be measured on the VCPX5 or VCPLab.
The lay length (twist / lay / pitch length) of conductors in jacketed cables, without removing the jacket: number of twists, minimum, maximum and average lay.
From 10 to 800 mm at the standard measuring length of 800 mm, with 1 mm accuracy. Other ranges are possible on request after sending samples.
Jacketed cables with an outer diameter from 2 mm; thin cables require a mounting adapter.